Are you over 18 and want to see adult content?
More Annotations
A complete backup of thehiltonorlando.com
Are you over 18 and want to see adult content?
A complete backup of greenpowerglobal.com
Are you over 18 and want to see adult content?
A complete backup of elantepenultimomohicano.com
Are you over 18 and want to see adult content?
A complete backup of evs-musikstiftung.ch
Are you over 18 and want to see adult content?
Favourite Annotations
A complete backup of kidsaintcheap.com
Are you over 18 and want to see adult content?
A complete backup of nestormakhno.info
Are you over 18 and want to see adult content?
A complete backup of comtessedubarry.com
Are you over 18 and want to see adult content?
A complete backup of simpla-template.org.ua
Are you over 18 and want to see adult content?
A complete backup of theroxyonsunset.com
Are you over 18 and want to see adult content?
A complete backup of wir-essen-gesund.de
Are you over 18 and want to see adult content?
A complete backup of goingcrazywannago.com
Are you over 18 and want to see adult content?
A complete backup of wildernesscommittee.org
Are you over 18 and want to see adult content?
Text
105· 113 : 46 - 50
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC.THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables rated TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors TYPE G & G-GC 2KV ROUND Type G-GC 3 and 4 Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil fully annealed, stranded, bare copper. 3 Conductors: Black, white, red Insulation: Premium-grade, color-coded 90ºC EPDM. Insulated grounds and 4 Conductors: Black, white, red, orange ground checks. Jacket: 90ºC, black. Temperature range: -40ºC to +90ºC. SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC.THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables rated TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors TYPE G & G-GC 2KV ROUND Type G-GC 3 and 4 Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil fully annealed, stranded, bare copper. 3 Conductors: Black, white, red Insulation: Premium-grade, color-coded 90ºC EPDM. Insulated grounds and 4 Conductors: Black, white, red, orange ground checks. Jacket: 90ºC, black. Temperature range: -40ºC to +90ºC. POWER DISTRIBUTION CABLE, CONTROL CIRCUIT CABLE 600V Single Conductor Wire. Description: 600V single conductor wire, sizes 18 AWG to 1550 MCM, with various jackets and insulations depending on environment and application.Can be direct burial, free air, conduit, open tray and underground ducts. Application: For use in a broad range of power, industrial, utility and commercial applications for power distribution and collection; plus control TYPE G & G-GC 2KV ROUND Type G-GC 3 and 4 Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil fully annealed, stranded, bare copper. 3 Conductors: Black, white, red Insulation: Premium-grade, color-coded 90ºC EPDM. Insulated grounds and 4 Conductors: Black, white, red, orange ground checks. Jacket: 90ºC, black. Temperature range: -40ºC to +90ºC.METRIC CONDUCTORS
10 0 7 160 60 93 280 37 21 70 855 1706 120 19 14.15 .558 731.20 1010 2000 127 41.45 1.632 6176 metric conductors TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. XLP PVC 600 V TC-ER MULTI 16 AWG FINAL Multi-Conductor XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 16 AWG fully annealed, stranded, bare copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 1, BARE COPPER STRANDED CONDUCTOR Stranded Conductor Bare or Tinned Soft (Annealed) APPLICATIONS For use in electrical grounding systems and on insulators for overhead transmission and distribution applications. COMPLETE CATALOG PRINTED UPDATED 4 8 09 t XHHW-2 XLP Insulation, 600 Volts APPLICATION: 1. General purpose wiring for lighting and power - residential, commercial, industrial buildings in accordance with National Electrical Code, maximum PVC 600 V TC-ER 4C FINAL 4C w/Ground PVC/Nylon PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 500 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon). Color-coded per ICEA Method 4; individual conductors colored black USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; POWER DISTRIBUTION CABLE, CONTROL CIRCUIT CABLE 600V Single Conductor Wire. Description: 600V single conductor wire, sizes 18 AWG to 1550 MCM, with various jackets and insulations depending on environment and application.Can be direct burial, free air, conduit, open tray and underground ducts. Application: For use in a broad range of power, industrial, utility and commercial applications for power distribution and collection; plus control USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables ratedPV CABLE 1KV
Single Conductor Copper XLP Type PV Direct Burial Type USE-2 or RHH/RHW-2 UL 1000V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: XLP thermosetting chemically cross-linked Polyethylene, surface printed. APPLICATIONS Photovoltaic wire for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in parts of the MC-HL ARMORED 15 KV EPR 3C FINAL 3 Conductors EPR PVC MC-HL/MV-105 15kV – 133% PRODUCT CONSTRUCTION Conductor: 2 AWG through 750 kcmil bare annealed copper per ASTM B3.Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072. Insulation: 220 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93 AMERICA’S WIRE COMPANY America’s Wire Company Dear Customer, We’re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of XHHW-2 RW90 VW-1 600V XHHW-2 XLP VW-1 600V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: Resistant to moisture, heat and flame. Jacket: Chemically cross-linked polyethylene. Temperature rating 90°C in wet and dry locations. All sizes pass the verticalflame test (VW-1).
SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; POWER DISTRIBUTION CABLE, CONTROL CIRCUIT CABLE 600V Single Conductor Wire. Description: 600V single conductor wire, sizes 18 AWG to 1550 MCM, with various jackets and insulations depending on environment and application.Can be direct burial, free air, conduit, open tray and underground ducts. Application: For use in a broad range of power, industrial, utility and commercial applications for power distribution and collection; plus control USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables ratedPV CABLE 1KV
Single Conductor Copper XLP Type PV Direct Burial Type USE-2 or RHH/RHW-2 UL 1000V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: XLP thermosetting chemically cross-linked Polyethylene, surface printed. APPLICATIONS Photovoltaic wire for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in parts of the MC-HL ARMORED 15 KV EPR 3C FINAL 3 Conductors EPR PVC MC-HL/MV-105 15kV – 133% PRODUCT CONSTRUCTION Conductor: 2 AWG through 750 kcmil bare annealed copper per ASTM B3.Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072. Insulation: 220 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93 AMERICA’S WIRE COMPANY America’s Wire Company Dear Customer, We’re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of XHHW-2 RW90 VW-1 600V XHHW-2 XLP VW-1 600V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: Resistant to moisture, heat and flame. Jacket: Chemically cross-linked polyethylene. Temperature rating 90°C in wet and dry locations. All sizes pass the verticalflame test (VW-1).
SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569. Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. May be used under the following conditions:Ventilated
THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; POWER DISTRIBUTION CABLE, CONTROL CIRCUIT CABLE 600V Single Conductor Wire. Description: 600V single conductor wire, sizes 18 AWG to 1550 MCM, with various jackets and insulations depending on environment and application.Can be direct burial, free air, conduit, open tray and underground ducts. Application: For use in a broad range of power, industrial, utility and commercial applications for power distribution and collection; plus control USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables ratedPV CABLE 1KV
Single Conductor Copper XLP Type PV Direct Burial Type USE-2 or RHH/RHW-2 UL 1000V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: XLP thermosetting chemically cross-linked Polyethylene, surface printed. APPLICATIONS Photovoltaic wire for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in parts of the MC-HL ARMORED 15 KV EPR 3C FINAL 3 Conductors EPR PVC MC-HL/MV-105 15kV – 133% PRODUCT CONSTRUCTION Conductor: 2 AWG through 750 kcmil bare annealed copper per ASTM B3.Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072. Insulation: 220 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93 AMERICA’S WIRE COMPANY America’s Wire Company Dear Customer, We’re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of XHHW-2 RW90 VW-1 600V XHHW-2 XLP VW-1 600V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: Resistant to moisture, heat and flame. Jacket: Chemically cross-linked polyethylene. Temperature rating 90°C in wet and dry locations. All sizes pass the verticalflame test (VW-1).
SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569.Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries.May be used under the following conditions:THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; SPECIALTY INDUSTRIAL COPPER WIRE & CABLE DISTRIBUTORABOUT USRESOURCESCONTACT USREQUEST QUOTEINSTRUMENTATIONTHERMOCOUPLE America's Wire Company Download USA Wire & Cable Catalog PDF. USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. MC CABLE, MC-HL CABLE, AIA CABLE Description: Jacketed, Metal Clad (MC), 600V, 5kV, 8kV and 15kV, 90°C, UL 1569.Types of armor include Aluminum Interlocked Armor (AIA) and Continuously Welded Sheath (MC-HL). Application: A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries.May be used under the following conditions:THWN OR THHN
THWN or THHN PVC Insulation, Nylon Jacket, 600 Volts APPLICATION: General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations and 75°C in wet locations, 600 volts, for installation in conduit orother
600V CLASS K WELDING CABLE Welding Cable Class K 30 AWG Stranding 600V PRODUCT CONSTRUCTION Conductor: 6 AWG through 500 kcmil fully annealed, stranded, bare copper, Class K. Jacket: Premium-grade 90ºC EPDM, black or red. Temperature range: -40ºC to +90ºC. APPLICATIONS For use with secondary voltage resistance welding leads and power supply applications not exceeding 600V AC. NATIONAL ELECTRICAL CODE ALLOWABLE AMPACITIES OF INSULATED 1.05 : 1.04 : 70 -77 : 26 - 30 1.00 : 1.00 : 78 - 86 : 31 - 35 .91 .94 .96 : 87 - 95 : 36 - 40 .82 .88 .91 : 96 - 104 : 41 - 45 .71 .82 .87 :105· 113 : 46 - 50
CAT 5E ARMORED CABLECLX CONNECTORS FOR CLX CABLE 24-4 Pr. CAT 5E PE/PVC Alum. Sheath Armor PVC Jacket PRODUCT CONSTRUCTION Conductor: 24 AWG solid bare copper Dielectric: Solid PE Assembly: Each pair has different lay length for crosstalk prevention and rip cord added. Inner Jacket: PVC Armor: A close-fitting, impervious, continuous, aluminum sheath Outer Jacket: Blue PVC CLASSIFICATIONS UL listed as Type MC, according to NEC Article 300 TYPE MP-GC - THREE CONDUCTOR - USA WIRE & CABLE TYPE MP-GC - Three Conductor Mine Power Cable XLP, Tape Shield, PVC or CPE Jacket, 8000 Volts APPLICATION: Shielded high voltage power distribution cable suitable for installation in boreholes, shafts, horizontal runs in underground USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical TYPE W 2KV MULTI-CONDUCTOR ROUND Type W Multi-Conductor EPDM 600V– 2kV PRODUCT CONSTRUCTION COLOR CODE* Conductor: 8 AWG through 500 kcmil, fully annealed, stranded, bare copper. 2 Conductors XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4; POWER DISTRIBUTION CABLE, CONTROL CIRCUIT CABLE 600V Single Conductor Wire. Description: 600V single conductor wire, sizes 18 AWG to 1550 MCM, with various jackets and insulations depending on environment and application.Can be direct burial, free air, conduit, open tray and underground ducts. Application: For use in a broad range of power, industrial, utility and commercial applications for power distribution and collection; plus control USE-2 OR RHW-2 OR RHH USE-2 or RHW-2 or RHH XLPE Insulation, 600 Volts APPLICATION: For lighting and power applications in accordance with the National Electrical Code and for other general purpose wiring applications. USE OR RHW-LS OR RHH VW-1 (LSZH) LOW-SMOKE, ZERO-HALOGEN USE or RHW-LS or RHH VW-1 (LSZH) Low-Smoke, Zero-Halogen XLP (LSZH) 600 VOLT, CLASS B APPLICATION: General purpose wiring for lighting and power-residential, commercial, industrial buildings in accordance with the National Electrical APPROXIMATE SHIPPING WEIGHTS (LBS/1000 FT) 6301 east stassney lane, suite 100 austin, texas 78744, usa 1-800-880-9473, fax 512-443-6329, sales@usawire-cable.com BENDING RADII AND PULLING TENSIONS BENDING RADII AND PULLING TENSIONS MINIMUM BENDING RADII Power Cables 600 Volts. without Sheath. Shielding or Armor . The minimum bending radii for single and multi-conductor cables rated XLP PVC 600 V TC-ER 3C FINAL 3C w/Ground XLP PVC Type TC-ER 600V PRODUCT CONSTRUCTION Conductor: 8 AWG through 1000 kcmil bare, annealed copper per ASTM B3.Class B stranding per ASTM B8. Insulation: Flame-retardant Cross-linked Polyethylene (XLP). Color-coded per ICEA Method 4;PV CABLE 1KV
Single Conductor Copper XLP Type PV Direct Burial Type USE-2 or RHH/RHW-2 UL 1000V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: XLP thermosetting chemically cross-linked Polyethylene, surface printed. APPLICATIONS Photovoltaic wire for use as interconnection wiring on solar panels in grounded or ungrounded systems as defined in parts of the XHHW-2 RW90 VW-1 600V XHHW-2 XLP VW-1 600V PRODUCT CONSTRUCTION Conductor: Single copper conductor, stranded. Insulation: Resistant to moisture, heat and flame. Jacket: Chemically cross-linked polyethylene. Temperature rating 90°C in wet and dry locations. All sizes pass the verticalflame test (VW-1).
MC-HL ARMORED 15 KV EPR 3C FINAL 3 Conductors EPR PVC MC-HL/MV-105 15kV – 133% PRODUCT CONSTRUCTION Conductor: 2 AWG through 750 kcmil bare annealed copper per ASTM B3.Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072. Insulation: 220 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93 AMERICA’S WIRE COMPANY America’s Wire Company Dear Customer, We’re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of Call: 800-880-9473Email Menu* Home
* About Us
* Products
* Instrumentation
* Thermocouple
* Control
* Tray Cable
* Portable Power
* Medium Voltage
* Armored Cable
* Single Conductor
* CMP Connectors
* USA Wire & Cable Catalog * USA Wire & Cable Line Card* Services
* Cable Management
* Resources
* Contact Us
* Request Quote
MASTER DISTRIBUTOR
OF SPECIALTY
INDUSTRIAL COPPER WIRE & CABLE Instrumentation ThermocoupleControl Tray Cable
Portable Power Medium Voltage Armored CableSingle Conductor
CMP
Connectors
AMERICA'S WIRE COMPANYDOWNLOAD USA WIRE & CABLE CATALOG PDF USA Wire & Cable, Inc. is a global distributor of electrical wire and cable serving all 50 states and shipping to more than 50 countries. With more than 250 years of combined experience, our personnel have the cable knowledge and experience needed to provide the specification review service relied upon by many of the top engineering and construction firms worldwide.Download USA Wire
& Cable Catalog PDFDownload Company Overview PDFContact Us TodayAPPLICATIONS
AND INDUSTRIES SERVEDPower
PlantRefiningPetrochemicalSolar energyNatural GasLiquified Natural GasOil & Gas USA WIRE & CABLE, INC.6320 East Stassney Lane Building 2, Suite 275Austin, Texas  78744 Toll-Free: 1-800-880-9473 Fax: 512-443-6329Email: inquiry@usawire-cable.comwww.usawire-cable.comLinks
* Home
* About Us
* Cable Management
* Resources
* Contact Us
* Request Quote
* Privacy Policy
* Sitemap
Products
* Instrumentation
* Thermocouple
* Control
* Tray Cable
* Portable Power
* Medium Voltage
* Armored Cable
* Single Conductor
* CMP Connectors
© 2017 USA Wire & Cable, Inc.Site created by Thomas Web Solutions ^Details
Copyright © 2024 ArchiveBay.com. All rights reserved. Terms of Use | Privacy Policy | DMCA | 2021 | Feedback | Advertising | RSS 2.0